Series V: balanced fresh-air ventilation with energy recovery

Balanced supply and exhaust ventilation with total-heat recovery and three-stage filtration, for new builds and renovations that need code-compliant fresh air. Series V does not dehumidify: pair it with Series R where humidity control is needed.

Price on request

Installed price after a site survey.

System details

Balanced ventilation with energy recovery

Series V supplies filtered outdoor air and extracts stale indoor air in equal measure. The two streams pass a total-heat recovery core that transfers heat and moisture from one to the other without mixing them, so the cooling in the exhaust is not thrown away. It does not dehumidify.

It is specified in new builds and renovations where a fresh-air rate is required and the dehumidification is handled by Series R on its own ducts.

  • Balanced supply and exhaust
  • Total-heat recovery core
  • Three filter stages on the intake
  • No dehumidification

Where the unit sits and how the air moves

Only the grilles and the wall controller stay visible. The unit, its ducts and its drain are above the ceiling.

  1. 01

    In the ceiling void

    Near an outside wall or riser for the two outdoor connections. Ceiling height: on the datasheet.

    Cut-away illustration of a ceiling void with a ventilator connected to four round ducts, two of them going to the outside wall
  2. 02

    Four ducts

    Outdoor intake and exhaust to weather-protected terminals kept apart; indoor supply to living rooms and bedrooms, extract from wet rooms.

    Isometric floor plan of an apartment with supply ducts to the bedrooms, extract ducts from the wet rooms and two facade terminals
  3. 03

    Drain and power

    Condensate connection (a total-heat core normally condenses little), power rating and controller route: on the datasheet.

    Illustration of a ceiling-void ventilator with its cable running down to a wall isolator and controller

Published figures only

Every row below comes from the manufacturer datasheet at its stated test conditions. A row without a published figure is marked, never guessed. Competitor pages in the UAE list contradictory filtration specs; ours cite the sheet.

The manufacturer datasheet for this family has not been published yet, so no figure is shown here: capacity, airflow, sound level and power are quoted per project after the survey, and the table fills in the day the datasheet arrives.

Installation requirements (for professionals)

What the MEP consultant or contractor needs to reserve before the unit arrives. Exact values are on the datasheet; our team confirms them on the survey.

  • Ceiling void and access

    Clear height and an access panel on the filter side. Values: on the datasheet.

  • Four duct connections

    Intake and exhaust terminals kept apart on the facade; supply and extract indoors. Spigot sizes: on the datasheet.

  • Condensate

    Whether a drain is required: on the datasheet.

  • Power and controls

    Supply rating and controller route: on the datasheet. Isolator within reach.

Engineering limits

Stated plainly, so nobody buys the wrong thing.

  • Does not dehumidify. For humidity control add Series R.
  • Does not cool. Temperature stays with the AC.
  • Never connected into the AC ductwork.
  • Sized by the fresh-air rate the occupants or the code require, not by floor area.

Where this system is specified

The spaces where we install it most, with what to look for in each.

Questions about this system

Short answers. The full list of questions is on the FAQ page.

Does Series V dehumidify?

No. It ventilates with energy recovery and filters the intake. For humidity control it is paired with Series R, each unit on its own ducts.

Series V or Series F?

Series F ventilates, recovers energy and dehumidifies in one unit. Series V ventilates and recovers energy only, and suits projects where the dehumidification is already handled or specified separately.

Can it be retrofitted?

Where there is a ceiling void with access to an outside wall or riser for the two outdoor ducts, yes. It is most often specified during a renovation or a new build, when duct routes are open.

How often are the filters changed?

On the datasheet interval for each stage; the washable pre-filter more often in dusty months. The controller shows when a filter is due.