Humidity basics1 min read

Why your house is humid even with the AC on

Oversized AC that short-cycles, supply air at 88% RH, sealed glazing and night-time humidity. Eight UAE causes, how to measure, the fix that holds 50% RH.

Secco team · Engineering team

The AC runs all day, the room is cold, and the hygrometer still says 65%. Eight causes explain it; most homes have two or three at once.

The eight causes

  1. An oversized AC that short-cycles. It cools the room in minutes and stops before it has condensed much water.
  2. Supply air that carries moisture. In a Dubai inspection reported by The National, the rooms read 64 to 70% and the air leaving the AC supply vent read 88.5%.
  3. A wet coil or blocked drain. Water sits in the unit and evaporates back into the airflow.
  4. Sealed glazing. Double-glazed high-rise units hold shower, cooking and laundry moisture indoors.
  5. Night-time humidity. Forecasts of 45% by day hide 60% overnight, when the AC also cycles less.
  6. Doors and windows left open to the balcony or garden in summer.
  7. Leaky ducts. Older villas may have cracks in ductwork or walls.
  8. The AC switched off for the day or a holiday: residents came back to mouldy homes.

How to measure it

Put a hygrometer at waist height in the bedroom, away from the vent. Read it at dawn and before bed for a week. See how to measure humidity at home.

What does not fix it

A colder set-point. The AC still stops at the temperature you choose, and colder surfaces sweat more.

The fix that holds 50%

Fix the drain and coil, close the envelope, stop drying laundry indoors. Then let a dehumidifier hold the set-point the AC cannot. See high indoor humidity.

Key points

  • An oversized AC cools fast and short-cycles, so it never runs long enough to dry the air.
  • Supply air can carry moisture: one Dubai tenant's inspection measured 88.5% RH at the vent.
  • Sealed glazing keeps shower, cooking and laundry moisture indoors; humidity peaks overnight at about 60%.
  • The fix is a dedicated dehumidifier controlled to 50% RH, not a colder AC setting.

Questions people ask

Can the AC itself be supplying the humidity?

Yes. In a case reported by The National, an inspection found 64 to 70% in the rooms and 88.5% at the AC supply vent. A dirty or waterlogged coil, a blocked drain or a unit that never runs long enough can all push wet air into the room.

How do I check?

Put a hygrometer in the bedroom away from the vent, read it at dawn and before bed for a week, and note the AC setting. Readings over 60% overnight while the AC runs mean the AC is not the answer.

What fixes it?

Fix the obvious sources first: AC drain and coil, balcony doors, laundry drying indoors. If the overnight reading still sits above 60%, a dehumidifier sized for the home holds the level the AC cannot.